Heat recovery single-room units. Maximum air capacity up to 53 m³/h.
USE | |
Arrangement of efficient energy-saving supply and exhaust single-room ventilation in flats, houses, cottages, social and commercial premises.Heat recovery minimises ventilation heat losses. | Humidity balance and controllable air exchange create individually set microclimate.Coordinated network based on several integrated single-room ventilation units with central control. |
DESIGN | |
HEAT AND MOISTURE REGENERATION | |
High-tech ceramic energy accumulator with heat recovery up to 90 %. | Due to its cellular structure it has a larger contact area surface and high efficiency. The energy accumulator is featured with excellent heat-conducting properties and thermal energy storage capacity. |
UNIT OPERATING LOGIC IN WINTER PERIOD | |
Warm stale air is extracted from the premise, flows through the ceramic regenerator and transfers a part of the accumulated heat and moisture to it.As the ceramic regenerator gets warmed up, the unit switches to the supply mode. | Clean cold intake air flows through the regenerator and absorbs accumulated heat and humidity.When the ceramic regenerator is cooled down, the unit is switched to the extract air mode. |
CONTROL | |
The integrated automation system enables operation of the unit at the first low speed or the second high speed:
The unit operation mode control is performed by means of an external control block with a power transformer:
|
|
To arrange a central controlled ventilation system based on 4 units connect three A50 / A50-1/ A50 S / A50-1 S units to one A50 Pro / A50-1 Pro / A50 S Pro / A50-1 S Pro unit with SEA-T12 control and power unit. No extra accessories are required. | |
To arrange a central controlled ventilation system based on more than 4 units connect a required number of the units, one SEA three-position switch and several 12 W AT-12 transformers or 40 W AT-40 transformers, depending on the total unit power consumption to one A50 / A50-1/ A50 S / A50-1 S unit. | |
MOUNTING | |
The unit is designed for external through-the-wall installation inside a prepared round hole in the outer wall of the building.The best ventilation solution is pairwise installation of reverse phase connected units. Some units supply fresh air to the room and the other units extract stale air from the room. This allows to arrange the most efficient balanced ventilation. | In case of brand new construction the units are mounted in two stages:
If mounting of the ventilation hood on the outer wall is undesirable it may be flush mounted and the external grille may be inserted into the outer window jamb using the KIT BlauPlast 204×60-1 pre-installation kit. Available upon separate order. |
Angular mounting into a wall with standard thickness using KIT BlauPlast 204×60-1 | |
Parameter | A50 (1 speed) | A50 (2 speed) | Measurement unit |
---|---|---|---|
Voltage | 220-240 | 220-240 | V |
Voltage | 220-240 | 220-240 | V |
Frequency | 50 | 50 | Hz |
Current | 0.021 | 0.026 | A |
Power | 3.68 | 4.83 | W |
RPM | 599 | 1155 | min-1 |
Air capacity | 26 | 53 | m³/h |
Sound pressure level at 1 m | 24 | 34 | dBА |
Outdoor sound pressure attenuation | 18 | 18 | dBА |
Sound pressure level at 3 m | 14 | 24 | dBА |
Regeneration efficiency | ≤ 90 | ≤ 90 | % |
Ingress protection rating | IP24 | IP24 | – |
SEC class | A | A | – |
Mounting | wall mounting | wall mounting | – |