Do you want to become our Business ! Partner?

Mini Cart

Northvent A50C3-1 S8 W V.2

0.00

Single-room heat recovery units with Wi-Fi control. Maximum air capacity up to 50 m³/h.

Description

FEATURES
Extended temperature range up to -30 °C.
Arrangement of efficient energy-saving, supply and exhaust, single-room ventilation in flats, houses, cottages, social and commercial premises.Reducing heat losses caused by ventilation due to heat recovery.Humidity balance and controllable air exchange create individually controlled microclimate.Wi-F i data exchange between several single-room ventilation units for coordinated operation.Controlled by Android or iOS smartphone or tablet.
DESIGN
  
One of the best heat recovery efficiency on the market due to innovative hexagonal structure of the heat exchanger cells.Built-in Wi-Fi for wireless communication between units and Android or iOS device control.Integrated automatic air shutters prevent air back drafting.Easy maintenance. Indoor unit is opened by pressing the latches on both sides. The specially designed front panel can be closed manually to ensure 100 % air tightness and protect against wind impact.
UNIT OPERATING LOGIC IN WINTER PERIOD
Warm stale air is extracted from the premise, flows through the ceramic heat exchanger and transfers its heat and moisture to it.As the ceramic heat exchanger gets warmed up, the unit switches to the supply mode.Clean cold intake air flows through the heat exchanger and absorbs accumulated heat and humidity.When the heat exchanger is cooled down, the unit switches to the extract air mode.
CONTROL
Unit control via smartphone or tablet application.The units can be connected by Wi-Fi for synchronized operation.House ventilation control via cloud service from anywhere in the world.
A50C3-1 S8 W V.2 either can operate as independent unit or can be connected with other units in a house and controlled with a master unit. In this case, only the master unit receives a signal from the remote control.

Northvent PRO app for Android or iOS devices is available at Google Play and App Store.

Connection to smart house or Building Management System (BMS) via Wi-Fi.Control of the unit operation mode is also performed by means of the sensor control panel located on the unit casing or the remote control.
Northvent Pro

A50C3-1 S8 W V.2 is equipped with a humidity sensor for indoor humidity control. If humidity increases above a set point, the unit boosts to the high speed independently on other units in the system.

MOUNTING
The unit is designed for through-the-wall installation inside a prepared hole in an outer wall of the building.The best ventilation solution is pairwise installation of reverse phase synchronized units. Some units ensure supply of fresh air to the room and the other units extract air from the premise. This way the most efficient balanced ventilation is arranged.In case of brand new construction, units are mounted in two stages:

  • Pre-installation of an air duct and an outer ventilation hood at the stage of indoor finishing and outer decorative wall finishing.
  • Completion of the installation before commissioning of a house. It includes installation of the indoor unit with controller and shutters, the cartridge, the heat exchanger, the fan and the filters.

Technical Data

ParametersExpert A50C3-1 S8 W V.2
SpeedIIIIII
Voltage [V / 50 (60) Hz]100-240
Capacity with hood heating element off [W]4,455,087,06
Capacity with hood heating element on [W]64,4565,0867,06
Current with hood heating element off [A]0,0350,0400,059
Current with hood heating element on [A]0,2950,3000,319
RPM [min⁻1]80013001900
Air flow in ventilation mode [m3/h (l/s)]15 (4)30 (8)50 (14)
Air flow in energy recovery mode [m3/h (l/s)]8 (2)15 (4)25 (7)
SFP [W/l/s]2,141,221,02
FilterG3 (Option: F8 PM2.5 > 99 %*)
Transported air temperature [°C]-30…+40
Sound pressure level at 1 m in accordance with ISO 3741:2004 [dBA]202733
Sound pressure level at 3 m in accordance with ISO 3741:2004 [dBA]111824
Outdoor sound pressure attenuation in accordance with DIN EN 20140 [dBA]42
Heat recovery efficiency in accordance with DIBt LÜ-A 20 [%] up to 93
Ingress protection ratingIP24
* maximum air flow 40 m3/h

Characteristics

ParameterExpert A50C3-1 S8 W V.2 (I speed)Expert A50C3-1 S8 W V.2 (II speed)Expert A50C3-1 S8 W V.2 (III speed)Measurement unit
Voltage100-240100-240100-240V
Frequency50/6050/6050/60Hz
Power with hood heating element off4,455,087,06W
Power with hood heating element on64,4565,0867,06W
Current with hood heating element on0,2950,3000,319A
Current with hood heating element off0,0350,0400,059A
RPM80013001900min-1
SFP2,141,221,02W/l/s
Air flow in ventilation mode4814l/s
Air flow in heat recovery mode247l/s
Air flow in ventilation mode153050m³/h
Air flow in heat recovery mode81525m³/h
Sound pressure level at 1 m in accordance with ISO 3741:2004202733dBА
Sound pressure level at 3 m in accordance with ISO 3741:2004111824dBА
EC motoryesyesyes
Temperature of transported air-30+40-30…+40-30…+40°С
Ingress protection ratingIP24IP24IP24
FilterG3 (Option: F8 PM2,5 > 99 %*)G3 (Option: F8 PM2,5 > 99 %*)G3 (Option: F8 PM2,5 > 99 %*)
Outdoor sound pressure attenuation in accordance with DIN EN 20140424242dBА
Heat recovery efficiency in accordance with DIBt LÜ-A 20up to 93up to 93up to 93%

Dimensions

Reviews

There are no reviews yet.

Be the first to review “Northvent A50C3-1 S8 W V.2”

Your email address will not be published. Required fields are marked *