Arrangement of efficient energy-saving, supply and exhaust, single-room ventilation in flats, houses, cottages, social and commercial premises. Reducing heat losses caused by ventilation due to heat recovery.Humidity balance and controllable air exchange create individually controlled microclimate.Wi-F i data exchange between several single-room ventilation units for coordinated operation.Controlled by Android or iOS smartphone or tablet.
Connection to smart house or Building Management System (BMS).
DESIGN
One of the best heat recovery efficiency on the market due to innovative hexagonal structure of the heat exchanger cells.
Built-in Wi-Fi for wireless communication between units and Android or iOS device control.
Integrated automatic air shutters prevent air back drafting.
Easy maintenance. Indoor unit is opened by pressing the latches on both sides. The specially designed front panel can be closed manually to ensure 100 % air tightness and protect against wind impact.
UNIT OPERATING LOGIC IN WINTER PERIOD
Warm stale air is extracted from the premise, flows through the ceramic heat exchanger and transfers its heat and moisture to it.As the ceramic heat exchanger gets warmed up, the unit switches to the supply mode.
Clean cold intake air flows through the heat exchanger and absorbs accumulated heat and humidity.When the heat exchanger is cooled down, the unit switches to the extract air mode.
CONTROL
Unit control via smartphone or tablet application.The units can be connected by Wi-Fi for synchronized operation.House ventilation control via cloud service from anywhere in the world.
Expert A100-1 W V.2 either can operate as independent unit or can be connected with other units in a house and controlled with a master unit. In this case, only the master unit receives a signal from the remote control.
Northhvent V.2 app for Android or iOS devices is available at Google Play and App Store.
Connection to smart house or Building Management System (BMS) via Wi-Fi.
Control of the unit operation mode is also performed by means of the sensor control panel located on the unit casing or the remote control.
Expert A100-1 W V.2 is equipped with a humidity sensor for indoor humidity control. If humidity increases above a set point, the unit boosts to the high speed independently on other units in the system.
MOUNTING
The unit is designed for through-the-wall installation inside a prepared hole in an outer wall of the building.The best ventilation solution is pairwise installation of reverse phase synchronized units. Some units ensure supply of fresh air to the room and the other units extract air from the premise. This way the most efficient balanced ventilation is arranged.
The Expert A100-1 W V.2 unit can also be installed in a bathroom and kitchen, if allowed by local building codes. Otherwise, the Expert Duo unit or an extract fan should be installed.
Technical Data
Parameters
Expert A100-1 S10 W V.2
Expert A100-1 S W V.2
Speed
I
II
III
MAX
Voltage [V / 50 (60) Hz]
100-240
Power [W]
3,20
4,00
6,60
18,00
Current [A]
0,037
0,046
0,071
0,151
RPM [min⁻1]
780
1100
1920
2940
Air flow in ventilation mode [m3/h (l/s)]
18 (5)
30 (8)
58 (16)
108 (30)
Air flow in energy recovery mode [m3/h (l/s)]
9 (3)
15 (4)
29 (8)
54 (15)
SFP [W/l/s]
1,28
0,96
0,82
1,20
Filter
G3 (Опция: F8 PM2.5 > 99 %*)
Transported air temperature [°C]
-30…+40
Sound pressure level at 1 m in accordance with ISO 3741:2004 [dBA]
23
27
40
51
Sound pressure level at 3 m in accordance with ISO 3741:2004 [dBA]
13
18
30
42
Outdoor sound pressure attenuation in accordance with DIN EN 20140 [dBA]
42
Heat recovery efficiency in accordance with DIBt LÜ-A 20 [%]
≤ 87
* maximum air flow 82 m3/h
Characteristics
Parameter
Expert A100-1 S10 W V.2 (Speed I)
Expert A100-1 S10 W V.2 (Speed II)
Expert A100-1 S10 W V.2 (Speed III)
Expert A100-1 S10 W V.2 (MAX)
Measurement unit
Voltage
100-240
100-240
100-240
100-240
V
Frequency
50/60
50/60
50/60
50/60
Hz
Fan power
3,20
4,00
6,60
18,00
W
Current
0,037
0,046
0,071
0,151
A
RPM
780
1100
1920
2940
min-1
Air flow in heat recovery mode
3
4
8
15
l/s
Air flow in ventilation mode
18
30
58
108
m³/h
SFP
1,28
0,96
0,82
1,20
W/l/s
Air flow in heat recovery mode
9
15
29
54
m³/h
Air flow in ventilation mode
5
8
16
30
l/s
Sound pressure level at 1 m in accordance with ISO 3741:2004
23
27
40
51
dBА
Sound pressure level at 3 m in accordance with ISO 3741:2004
13
18
30
42
dBА
EC motor
yes
yes
yes
yes
–
Temperature of transported air
-20 … +40
-20 … +40
-20 … +40
-20 … +40
°С
Filter
G3 (Option: F8 PM2,5 > 99 %*)
G3 (Option: F8 PM2,5 > 99 %*)
G3 (Option: F8 PM2,5 > 99 %*)
G3 (Option: F8 PM2,5 > 99 %*)
–
Outdoor sound pressure attenuation in accordance with DIN EN 20140
42
42
42
42
dBА
Dimensions
Reviews
There are no reviews yet.
Be the first to review “Northvent Expert A100-1 W V.2” Cancel reply
Reviews
There are no reviews yet.