Do you want to become our Business ! Partner?

Mini Cart

Description

USE
Arrangement of efficient energy-saving supply and exhaust single-room ventilation in flats, houses, cottages, social and commercial premises. Heat recovery minimises ventilation heat losses.

 

Humidity balance and controllable air exchange create individually set microclimate.
DESIGN
HEAT AND MOISTURE REGENERATION
High-tech ceramic energy accumulator with heat recovery up to 85 %. Due to its cellular structure it has a larger contact area surface and high efficiency. The energy accumulator is featured with excellent heatconducting properties and thermal energy storage capacity.
UNIT OPERATING LOGIC IN WINTER PERIOD
Warm stale air is extracted from the premise, flows through the ceramic regenerator and transfers a part of the accumulated heat and moisture to it. As the ceramic regenerator gets warmed up, the unit switches to the supply mode.

 

Clean cold intake air flows through the regenerator and absorbs accumulated heat and humidity.When the ceramic regenerator is cooled down, the unit is switched to the extract air mode.
CONTROL
The unit operation mode control is performed by means of manual three-position switches located on the unit casing or using the remote controller.The unit is equipped with a humidity sensor for indoor humidity control and regulation.
Remote control and operation mode selection:
MOUNTING
The unit is designed for external through-the-wall installation inside a prepared round hole in the outer wall of the building.The best ventilation solution is pairwise installation of reverse phase connected units. Some units supply fresh air to the room and the other units extract stale air from the room. This allows to arrange the most efficient balanced ventilation. In case of brand new construction the units are mounted in two stages:

  • pre-installation at the stage of the indoor finishing and outer decorative wall finishing. It includes installation of the telescopic air ducts, outer ventilation hood and laying out of electric cables.
  • final mounting before commissioning of a house. It includes installation of the regenerator, the filters, connection of the ventilation unit.

If mounting of the ventilation hood on the outer wall is undesirable it may be flush mounted and the external grille may be inserted into the outer window jamb using the KIT BlauPlast 204×60-2 pre-installation kit. Available upon separate order.

Angular mounting into a wall with standard thickness using KIT BlauPlast 204х60-2

Characteristics

ParameterErgo A25-1 Pro (1 speed)Ergo A25-1 Pro (2 speed)Ergo A25-1 Pro (3 speed)Measurement unit
Voltage100-230100-230100-230V
Voltage100-230100-230100-230V
Frequency50/6050/6050/60Hz
Current0.0240.0270.038A
Power3.684.155.59W
RPM125013972541min-1
Air capacity71625m³/h
Sound pressure level at 1 m313543dBА
Outdoor sound pressure attenuation191919dBА
Sound pressure level at 3 m222533dBА
Regeneration efficiency≤ 85≤ 85≤ 85%
Ingress protection ratingIP24IP24IP24
SEC classAAA
Mountingwall mountingwall mountingwall mounting

Dimensions

Reviews

There are no reviews yet.

Be the first to review “Northvent Ergo A25-1 Pro”