Do you want to become our Business ! Partner?

Mini Cart

Northvent ECO A50-4 Pro

0.00

Single-room heat recovery units with Wi-Fi control. Maximum air capacity up to 50 m³/h.

Description

FEATURES
Arrangement of efficient energy-saving supply and exhaust single-room ventilation in flats, houses, cottages, social and commercial premises. Air purification with optional F8 filter PM2.5 > 99 %. Protection from outdoor noise. Reducing heat losses caused by ventilation due to heat recovery. Humidity balance and regulated air exchange create individually controlled microclimate.
DESIGN
UNIT OPERATING LOGIC IN WINTER PERIOD
Warm stale air is extracted from the premise, flows through the ceramic regenerator and transfers its heat energy and moisture to it. As the ceramic regenerator gets warmed up, the unit switches to the supply mode. Clean cold intake air flows through the regenerator and absorbs accumulated heat and humidity. When the ceramic regenerator is cooled down, the unit switches to the extract air mode.
CONTROL
Control of the unit operation mode is performed by means of the sensor control panel.
One control panel with sensor buttons can control up to two units. Low voltage (12 V) power supply between control panel and Eco units.
MOUNTING
The unit is designed for through-the-wall installation inside a prepared hole in an outer wall of the building. One unit is able to ventilate a room up to 25 m2. For bigger rooms two or more units must be installed.

Technical Data

Parameters ECO A50-4 S11 Pro
ECO A50-4 S Pro
Speed 1 2 3
Voltage [V / 50 (60) Hz] 100-240
Power [W] 1.00 2.10 4.30
Current [A] 0.017 0.025 0.041
RPM [min⁻¹] 915 1555 2330
Air flow in ventilation mode [m³/h (l/s)] 15 (4) 30 (8) 50 (14)
Air flow in heat recovery mode [m³/h (l/s)] 8 (2) 15 (4) 25 (7)
Filter G3 (Option: F8 PM2,5 > 99 %*)
Transported air temperature [°C] -20(-30**) … +40
Outdoor sound pressure attenuation [dBA] according to DIN EN 20140 21 27 29
Regeneration efficiency [%] In accordance with DIBt LÜ-A 20 12 18 20
Sound pressure level at 1 m [dBA] In accordance with ISO 3741: 2004 41
Sound pressure level at 3 m [dBA] In accordance with ISO 3741: 2004 up to 92
SEC Class  A
Ingress protection rating IP24
* maximum air flow 40 m3/h
** with ZL1 160/100 cartridge and AH-8 outer hood applied

Designation Key

Model Air duct Nominal air flow [m³/h] Internal grille type Hood type Control
Eco A: round air duct 50 4 S11:plastic hood for standard walls
S: metal hood for thin walls
Pro: sensor control panel

Characteristics

Parameter ECO A50-4 S Pro (1 speed) ECO A50-4 S Pro (2 speed) ECO A50-4 S Pro (3 speed) Measurement unit
Voltage 100-240 100-240 100-240 V
Frequency 50/60 50/60 50/60 Hz
Current 0.017 0.025 0.041 A
Power 1.00 2.10 4.30 W
RPM 915 1555 2330 min-1
Air flow in ventilation mode 4 8 14 l/s
Air flow in heat recovery mode 2 4 7 l/s
Air flow in ventilation mode 15 30 50 m³/h
Air flow in heat recovery mode 8 15 25 m³/h
Sound pressure level at 1 m in accordance with ISO 3741:2004 21 27 29 dBА
Sound pressure level at 3 m in accordance with ISO 3741:2004 12 18 20 dBА
Temperature of transported air 20(-30**) … +40 20(-30**) … +40 20(-30**) … +40 °С
EC motor yes yes yes
Ingress protection rating IP24 IP24 IP24
Filter G3 (Option: F8 PM2,5 > 99 %*) G3 (Option: F8 PM2,5 > 99 %*) G3 (Option: F8 PM2,5 > 99 %*)
Outdoor sound pressure attenuation in accordance with DIN EN 20140 41 41 41 dBА
SEC class A A A
Mounting wall mounting wall mounting wall mounting
Heat recovery efficiency in accordance with DIBt LÜ-A 20 up to 92 up to 92 up to 92 %

Reviews

There are no reviews yet.

Be the first to review “Northvent ECO A50-4 Pro”

Your email address will not be published. Required fields are marked *

website design in uk